Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 45-52, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32111365

RESUMO

This article provides an analysis of the results obtained in 2017 by the participants inscribed in the External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), which includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. The results obtained in 2017 confirm the excellent skill and good technical standards found in previous editions. However, the programme again showed that erroneous results can be obtained in any laboratory and even in clinically relevant determinations. Once again, the results of this program highlight the need to implement both internal and external controls, as in the SEIMC programme.


Assuntos
Infectologia/normas , Laboratórios/normas , Microbiologia/normas , Controle de Qualidade , Bacteriologia , Humanos , Micologia , Espanha
2.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 53-60, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32111366

RESUMO

This article provides an analysis of the results obtained in 2018 by the participants inscribed in the External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), which includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. The results obtained in 2018 confirm the excellent skill and good technical standards found in the vast majority of Spanish clinical microbiology laboratories, as shown in previous editions. However, the programme again shows that erroneous results can be obtained in any laboratory and even in clinically relevant determinations. Once again, the results of this programme highlight the need to implement both internal and external controls, as in the SEIMC programme.


Assuntos
Infectologia/normas , Laboratórios/normas , Microbiologia/normas , Controle de Qualidade , Bacteriologia , Humanos , Micologia , Espanha
3.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 61-66, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32111367

RESUMO

BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarised the results obtained from the 2017 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads and HCV genotyping. METHODS AND RESULTS: In the HIV-1 programme, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (35% on average) obtained values outside the accepted range (mean±0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was good, with up to 94% of laboratories reporting results within the limits (D<0.5 log10 copies/mL). The HBV and HCV programme consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 87% in that of HBV, obtained all the results within the accepted range (mean±1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability observed, it is advisable to use the same method and laboratory for patient follow-up.


Assuntos
Infecções por HIV , Hepatite B , Hepatite C , Controle de Qualidade , Carga Viral , Infecções por HIV/diagnóstico , HIV-1 , Hepacivirus , Hepatite B/diagnóstico , Vírus da Hepatite B , Hepatite C/diagnóstico , Humanos , Infectologia/normas
4.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 67-72, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32111368

RESUMO

BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarised the results obtained from the 2018 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads and HCV genotyping. METHODS AND RESULTS: In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (28% on average) obtained values outside the accepted range (mean±0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was good, with most laboratories reporting results within the limits (D<0.5 log10 copies/mL). The HBV and HCV programme consisted of two standards with different viral load contents. Most of the participants, 87% in the case of HCV and 88% in the HBV, obtained all the results within the accepted range (mean±1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow-up.


Assuntos
Infecções por HIV , Hepatite B , Hepatite C , Controle de Qualidade , Carga Viral , Infecções por HIV/diagnóstico , HIV-1 , Hepacivirus , Hepatite B/diagnóstico , Vírus da Hepatite B , Hepatite C/diagnóstico , Humanos , Infectologia/normas
5.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 38(supl.1): 45-52, ene. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-201386

RESUMO

Se presenta el análisis anual de los resultados remitidos durante el año 2017 por los participantes inscritos en el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC), que incluye las áreas de bacteriología, serología, micología, parasitología, micobacterias, virología, microbiología molecular y de detección genotípica de mecanismos de resistencia bacteriana. Los resultados obtenidos por los centros participantes resaltan, de nuevo, la adecuada capacitación de la inmensa mayoría de los laboratorios españoles de microbiología clínica, como ya venía sucediendo en los últimos años. Sin embargo, el programa muestra de nuevo que es posible obtener un resultado erróneo, incluso en determinaciones de la mayor trascendencia y en cualquier laboratorio. Una vez más, se destaca la importancia de complementar el control interno que cada laboratorio lleve a cabo con estudios de intercomparación externos, como los que ofrece el Programa SEIMC


This article provides an analysis of the results obtained in 2017 by the participants inscribed in the External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), which includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. The results obtained in 2017 confirm the excellent skill and good technical standards found in previous editions. However, the programme again showed that erroneous results can be obtained in any laboratory and even in clinically relevant determinations. Once again, the results of this program highlight the need to implement both internal and external controls, as in the SEIMC programme


Assuntos
Humanos , Técnicas de Laboratório Clínico/normas , Doenças Transmissíveis/diagnóstico , Controle de Qualidade , Avaliação de Programas e Projetos de Saúde , Sociedades Médicas , Microbiologia , Espanha
6.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 38(supl.1): 53-60, ene. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-201387

RESUMO

Se presenta el análisis anual de los resultados remitidos durante el año 2018 por los participantes inscritos en el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC), que incluye las áreas de bacteriología, serología, micología, parasitología, micobacterias, virología, microbiología molecular y detección genotípica de mecanismos de resistencia bacteriana. Los resultados obtenidos por los centros participantes resaltan significativamente la adecuada capacitación de la inmensa mayoría de los laboratorios españoles de microbiología clínica, tal como ya venía evidenciándose en los últimos años. Sin embargo, el Programa muestra de nuevo que es posible obtener un resultado erróneo, incluso en determinaciones de la mayor trascendencia y en cualquier laboratorio. Una vez más, se destaca la importancia de complementar el control interno que cada laboratorio lleve a cabo con estudios de intercomparación externos, como los que ofrece el Programa SEIMC


This article provides an analysis of the results obtained in 2018 by the participants inscribed in the External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), which includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. The results obtained in 2018 confirm the excellent skill and good technical standards found in the vast majority of Spanish clinical microbiology laboratories, as shown in previous editions. However, the programme again shows that erroneous results can be obtained in any laboratory and even in clinically relevant determinations. Once again, the results of this programme highlight the need to implement both internal and external controls, as in the SEIMC programme


Assuntos
Humanos , Técnicas de Laboratório Clínico/normas , Doenças Transmissíveis/diagnóstico , Controle de Qualidade , Avaliação de Programas e Projetos de Saúde , Sociedades Médicas , Microbiologia , Espanha
7.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 38(supl.1): 61-66, ene. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-201388

RESUMO

FUNDAMENTOS: Las determinaciones microbiológicas de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1), de la hepatitis C (VHC) y de la hepatitis B (VHB) son fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados, entre ellas se encuentran los programas de intercomparación externos, como es el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En el presente número se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de carga viral de estos virus, incluyendo el genotipado del VHC, realizado durante el año 2017. MÉTODOS Y RESULTADOS: En el control de VIH-1 se remitieron 5 estándares, de los que uno (plasma humano seronegativo) no contenía el virus, y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 2-5 log10 copias/ml. Una parte significativa de los laboratorios obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml), dependiendo del estándar y del método empleado, en promedio el 35% de los centros. La repetibilidad fue buena, y más del 94% de los laboratorios obtuvieron resultados aceptables (D < 0,5 log10 copias/ml). En los controles de VHC y VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes, un 82% en el caso del VHC y un 87% en el del VHB, obtuvo ambos resultados dentro de los límites de la media±1,96 DE log10 UI/ml. CONCLUSIONES: Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos. Debido a la variabilidad interlaboratorio observada, es aconsejable utilizar el mismo método y laboratorio en el seguimiento de los pacientes


BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarised the results obtained from the 2017 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads and HCV genotyping. METHODS AND RESULTS: In the HIV-1 programme, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (35% on average) obtained values outside the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was good, with up to 94% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV programme consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 87% in that of HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability observed, it is advisable to use the same method and laboratory for patient follow-up


Assuntos
Humanos , HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Técnicas de Laboratório Clínico/normas , Controle de Qualidade , Carga Viral/normas , Sociedades Médicas , Avaliação de Programas e Projetos de Saúde , Espanha
8.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 38(supl.1): 67-72, ene. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-201389

RESUMO

FUNDAMENTOS: Las determinaciones microbiológicas de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1), de la hepatitis C (VHC) y de la hepatitis B (VHB) son fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados, entre ellas se encuentran los programas de intercomparación externos, como el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En el presente artículo se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de carga viral de estos virus y el genotipado del VHC realizado durante el año 2018. MÉTODOS Y RESULTADOS: En el control de VIH-1 se remitieron 5 estándares, de los que uno (plasma humano seronegativo) no contenía el virus, y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 2-5 log10 copias/ml. Una parte significativa de los laboratorios participantes obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml), dependiendo del estándar y del método empleado, en promedio el 26% de los centros. La repetibilidad fue buena, y la mayoría de los laboratorios obtuvieron resultados aceptables (D < 0,5 log10 copias/ml). En los controles de VHC y VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes, un 87% en el caso del VHC y un 88% en el del VHB, obtuvo ambos resultados dentro de los límites de la media ± 1,96 DE log10 UI/ml. CONCLUSIONES: Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos. Debido a la variabilidad interlaboratorio, es aconsejable utilizar un mismo método y el mismo laboratorio en el seguimiento de los pacientes


BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarised the results obtained from the 2018 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads and HCV genotyping. METHODS AND RESULTS: In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (28% on average) obtained values outside the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was good, with most laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV programme consisted of two standards with different viral load contents. Most of the participants, 87% in the case of HCV and 88% in the HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow-up


Assuntos
Humanos , HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Técnicas de Laboratório Clínico/normas , Controle de Qualidade , Carga Viral/normas , Sociedades Médicas , Avaliação de Programas e Projetos de Saúde , Espanha
9.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 37(supl.1): 1-18, mayo 2019. tab
Artigo em Espanhol | IBECS | ID: ibc-189723

RESUMO

Se presenta el análisis anual de los resultados remitidos durante el año 2016 por los participantes inscritos en el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC), que incluye las áreas de bacteriología, serología, micología, parasitología, micobacterias, virología, microbiología molecular y genotipos de resistencia bacteriana. Los resultados obtenidos por los centros participantes destacan, de nuevo, la adecuada capacitación de la inmensa mayoría de los laboratorios españoles de microbiología clínica, como ya iba sucediendo en los últimos años. Sin embargo, el programa muestra que es posible obtener un resultado erróneo, incluso en determinaciones de la mayor trascendencia y en cualquier laboratorio. Una vez más, se resalta la importancia de complementar el control interno que lleva a cabo cada laboratorio con estudios de intercomparación externos, como los que ofrece el Programa de Control de Calidad SEIMC. Información sobre el suplemento: este artículo forma parte del suplemento titulado "Programa de Control de Calidad Externo SEIMC. Año 2016", que ha sido patrocinado por Roche, Vircell Microbiologists, Abbott Molecular y Francisco Soria Melguizo, S.A


The External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. As in previous years, the results obtained in 2016 confirm the excellent skill and good technical standards in the vast majority of clinical microbiology laboratories in Spain. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this programme highlight the need to implement both internal and external controls. Supplement information: This article is part of a supplement entitled "SEIMC External Quality Control Programme. Year 2016", which is sponsored by Roche, Vircell Microbiologists, Abbott Molecular and Francisco Soria Melguizo, S.A


Assuntos
Humanos , Avaliação de Resultados em Cuidados de Saúde/normas , Sociedades Médicas/normas , Controle de Qualidade , Análise de Dados , Sorologia/normas , Biologia Molecular , Bacteriologia/normas , Técnicas Bacteriológicas/normas , Virologia/normas
10.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 37(supl.1): 9-14, mayo 2019. tab
Artigo em Espanhol | IBECS | ID: ibc-189724

RESUMO

FUNDAMENTOS: Las determinaciones microbiológicas de la carga viral de los virus de la inmunodeficiencia humana de tipo 1 (VIH-1), de la hepatitis C (VHC) y de la hepatitis B (VHB) son fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados; entre ellas se encuentran los programas de intercomparación externos, como el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En este artículo se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de Carga Viral de estos virus, incluyendo el genotipado del VHC, realizado durante el año 2016. Métodos y resultados: En el control del VIH-1 se remitieron 5 estándares, de los cuales uno (plasma humano seronegativo) no contenía el virus y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 2 y 5 log10 copias/ml. Una parte considerable de los laboratorios obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml), en función del estándar y del método empleado, con un término medio del 40% de los centros. En los controles de VHC y VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes, el 86,5% en el caso del VHC y el 85,6% en el del VHB, obtuvo ambos resultados dentro de los límites de la media ± 1,96 DE log10 UI/ml. CONCLUSIONES: Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos. Debido a la variabilidad interlaboratorio, es aconsejable utilizar el mismo método y el mismo laboratorio en el seguimiento de los pacientes. Información sobre el suplemento: Este artículo forma parte del suplemento titulado "Programa de Control de Calidad Externo SEIMC. Año 2016", que ha sido patrocinado por Roche, Vircell Microbiologists, Abbott Molecular y Francisco Soria Melguizo, S.A


BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most important markers for the follow-up of patients infected with these viruses. Microbiology laboratories have a variety of tools to ensure the accuracy of the results obtained, including external quality control programmes such as that of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC). This article summarises the results of the 2016 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. Methods and results: In the HIV-1 programme, a total of 5 standards were sent. One standard consisted of seronegative human plasma, while the remaining 4 contained plasma from 3 different viremic patients, in the range of 2-5 log10 copies/mL. A significant proportion of the laboratories (40% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. The HBV and HCV programme consisted of 2 standards with different viral load contents. Most of the participants, 86.5% in the case of HCV and 85.6% in the case of HBV, obtained results that were all within the accepted range (mean ± 1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow-up. Supplement information: This article is part of a supplement entitled "SEIMC External Quality Control Programme. Year 2016", which is sponsored by Roche, Vircell Microbiologists, Abbott Molecular and Francisco Soria Melguizo, S.A


Assuntos
Humanos , Infecções por HIV/epidemiologia , HIV-1 , Hepacivirus , Vírus da Hepatite B , Sociedades Médicas/normas , Controle de Qualidade , Avaliação de Resultados em Cuidados de Saúde/normas
11.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 35(supl.3): 1-8, oct. 2017. tab
Artigo em Espanhol | IBECS | ID: ibc-170744

RESUMO

Se presenta el análisis anual de los resultados informados durante el año 2015 por los participantes inscritos en el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC), que incluye las áreas de bacteriología, serología, micología, parasitología, micobacterias, virología y microbiología molecular. Los resultados obtenidos por los centros participantes resaltan la adecuada capacitación de la gran mayoría de los laboratorios españoles de microbiología clínica. A pesar de ello, este programa muestra que es posible obtener un resultado erróneo, incluso en determinaciones de la mayor trascendencia. Una vez más, se destaca la importancia de complementar el control interno que realice cada laboratorio con estudios de intercomparación externos como los que ofrece el Programa de Control de Calidad SEIMC (AU)


The Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) External Quality Assessment Scheme includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2015 quality assessment schemes. As a whole, the results obtained in 2015 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in clinically relevant tests. Once again, the results of this programme highlight the need to implement both internal and external controls in order to ensure the optimal quality of microbiological tests (AU)


Assuntos
Humanos , Avaliação de Programas e Projetos de Saúde/métodos , Controle de Qualidade , Microbiologia/organização & administração , Microbiologia/normas , Bacteriologia/normas , Infectologia/métodos , Sociedades Médicas/organização & administração , Sociedades Médicas/normas , Micologia/organização & administração , Análise de Dados
12.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 35(supl.3): 9-14, oct. 2017. tab
Artigo em Espanhol | IBECS | ID: ibc-170745

RESUMO

Fundamentos: Las determinaciones de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1), de la hepatitis C (VHC) y de la hepatitis B (VHB) son marcadores microbiológicos fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados, entre ellas se encuentran los programas de intercomparación externos, como es el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En el presente número se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de carga viral de estos virus, incluyendo el genotipado del VHC, realizado durante el año 2015. Métodos y resultados: En el control del VIH-1 se remitieron 5 estándares, de los que 1 (plasma humano seronegativo) no contenía el virus y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 2-5 log10 copias/ml; 2 de ellos eran idénticos, con el fin de analizar la repetibilidad. Una parte significativa de los laboratorios obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml), dependiendo del estándar y del método empleado, en promedio el 26,6% de los centros. La repetibilidad fue excelente, y el 97,9% de los laboratorios obtuvo resultados aceptables (D < 0,5 log10 copias/ml). En los controles del VHC y del VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes, un 88,5% en el caso del VHC y un 85,5% en el del VHB, obtuvo ambos resultados dentro de los límites de la media ± 1,96 DE log10 UI/ml. Conclusiones: Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos, incluyendo la fase postanalítica. Debido a la variabilidad interlaboratorio es aconsejable utilizar un mismo método y el mismo laboratorio en el seguimiento de los pacientes (AU)


Background: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality assessment schemes are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarises the results obtained in the 2015 SEIMC External Quality Assessment Scheme for HIV-1, HCV, and HBV viral loads. Methods and results: In the HIV-1 programme, a total of 5 standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viraemic patients, in the range of 2-5 log10 copies/mL; 2 of these standards were identical, aiming to determine repeatability. A significant proportion of the laboratories (26.6% on average) obtained values outside the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and method used for quantification. Repeatability was excellent, with up to 97.9% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV programmes consisted of two standards with different viral load contents. Most of the participants, 88.5% in the case of HCV and 85.5% in the case of HBV, obtained all results within the accepted range (mean ± 1.96 SD log10 IU/mL). Conclusions: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase in the overall quality. Due to the notable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up (AU)


Assuntos
Humanos , Controle de Qualidade , Carga Viral/métodos , Vírus da Hepatite B/isolamento & purificação , Hepacivirus/isolamento & purificação , HIV-1/isolamento & purificação , Carga Viral/normas , Hepatite C/epidemiologia , Hepatite C/microbiologia , Hepatite B/epidemiologia , Hepatite B/microbiologia , Síndrome de Imunodeficiência Adquirida/microbiologia , Biomarcadores , Sociedades Médicas/organização & administração , Sociedades Médicas/normas
13.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 34(supl.3): 1-7, jul. 2016. tab
Artigo em Espanhol | IBECS | ID: ibc-170847

RESUMO

Se presenta el análisis anual de los resultados remitidos durante el año 2014 por los participantes inscritos en el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC), que incluye las áreas de bacteriología, serología, micología, parasitología, micobacteriología, virología y microbiología molecular. Los resultados obtenidos por los centros participantes resaltan, de nuevo, la adecuada capacitación de la gran mayoría de los laboratorios españoles de microbiología clínica, como ya venía sucediendo en los últimos años. Sin embargo, el programa muestra que es posible obtener resultados erróneos, incluso en determinaciones con importante trascendencia y en cualquier laboratorio. Una vez más, se destaca la importancia de complementar el control interno que cada laboratorio lleva a cabo con estudios de intercomparación externos, como los que ofrece el programa SEIMC


The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2014 controls. As a whole, the results obtained in 2014 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of the SEIMC program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests


Assuntos
Controle de Qualidade , Laboratórios/normas , Doenças Transmissíveis/diagnóstico , Virologia/normas , Bacteriologia/normas , Micologia/normas , Espanha , Padrões de Referência
14.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 34(supl.3): 8-13, jul. 2016. tab
Artigo em Espanhol | IBECS | ID: ibc-170848

RESUMO

Las determinaciones de la carga viral del virus de la inmunodeficiencia humana tipo 1 (VIH-1), del virus de la hepatitis C (VHC) y del virus de la hepatitis B (VHB) son marcadores microbiológicos fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados; entre ellas se encuentran los programas de intercomparación externos, como es el Programa de Control de Calidad Externo de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En el presente número se muestra el análisis de resultados del Programa de Control de Calidad Externo SEIMC de carga viral de estos virus, incluyendo el genotipado del VHC, realizado durante el año 2014. En el control de VIH-1 se remitieron 5 estándares, de los que uno (plasma humano seronegativo) no contenía el virus y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 2-5 log10 copias/ml. Con el fin de analizar la repetibilidad, 2 de ellos eran idénticos. Una parte significativa de los laboratorios obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml), dependiendo del estándar y del método empleado: en promedio el 30,8% de los centros. La repetibilidad fue excelente y el 95,8% de los laboratorios obtuvieron resultados aceptables (Δ < 0,5 log10 copias/ml). En los controles de VHC y VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes (un 83,7% en el caso del VHC y un 87,9% en el del VHB) obtuvo ambos resultados dentro de los límites de la media ± 1,96 desviaciones estándar log10 UI/ml. Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos, incluyendo la fase post-analítica. Debido a la variabilidad interlaboratorio, es aconsejable utilizar un mismo método y el mismo laboratorio en el seguimiento de los pacientes


Human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarizes the results obtained from the 2014 SEIMC (Spanish Society of Infectious Diseases and Clinical Microbiology) External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of 5 standards were sent. One standard consisted in seronegative human plasma, while the remaining 4 contained plasma from 3 different viremic patients, in the range of 2-5 log10 copies/mL; 2 of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (30.8% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/ mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 95.8% of laboratories reporting results within the limits (Δ < 0.5 log10 copies/mL). The HBV and HCV program consisted of 2 standards with different viral load contents. Most of the participants, 83.7% in the case of HCV and 87.9% in the HBV, obtained all the results within the accepted range (mean ± 1.96 standard deviations log10 IU/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up


Assuntos
Humanos , Vírus da Hepatite B , Controle de Qualidade , Carga Viral/normas , Laboratórios/normas , Hepacivirus , HIV-1 , Espanha
15.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 33(supl.2): 1-8, jul. 2015. tab
Artigo em Espanhol | IBECS | ID: ibc-140498

RESUMO

El Programa de Control de Calidad Externo de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica incluye las áreas de bacteriología trimestral y mensual, serología, micología, parasitología, micobacterias, virología, microbiología molecular y cargas virales del virus de la inmunodeficiencia humana-1, virus de la hepatitis C y virus de la hepatitis B. En este manuscrito se presenta el análisis de los resultados remitidos por los participantes en los controles enviados durante el año 2013, exceptuando los correspondientes a cargas virales, que se presentan en un manuscrito aparte. Los resultados obtenidos con- firman de nuevo la buena capacitación general de los laboratorios españoles de microbiología clínica, como ha venido sucediendo en los años anteriores. A pesar de ello, el programa muestra que es posible obtener un resultado erróneo, incluso en determinaciones de la mayor trascendencia y en cualquier laboratorio. Resaltamos la importancia de complementar el control interno que cada laboratorio lleva a cabo con estudios de intercomparación externos, como los que ofrece el Programa de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica


The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology and HIV-1, HCV and HBV viral loads. This manuscript presents the analysis of results obtained of the participants from the 2013 SEIMC External Quality Control Programme, except viral loads controls, that they are summarized in a manuscript abroad. As a whole, the results obtained in 2013 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests


Assuntos
Feminino , Humanos , Masculino , Controle de Qualidade , Sociedades Médicas/organização & administração , Sociedades Médicas/normas , Sociedades Médicas , Microbiologia/educação , Microbiologia/organização & administração , Microbiologia/normas , Imunoensaio/métodos , Avaliação de Resultados em Cuidados de Saúde/métodos , Sorologia/métodos , Sorologia/tendências , Análise de Dados/métodos , Análise de Dados/estatística & dados numéricos , Virologia/métodos , Virologia/tendências , Fenômenos Microbiológicos , Bacteriologia/organização & administração , Bacteriologia/normas
16.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 33(supl.2): 9-14, jul. 2015. tab
Artigo em Espanhol | IBECS | ID: ibc-140499

RESUMO

Las determinaciones de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1), de la hepatitis C (VHC) y de la hepatitis B (VHB) son marcadores microbiológicos fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados; entre ellas se encuentran los programas de intercomparación externos, como es el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En el presente número se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de carga viral de estos virus, incluyendo el genotipado del VHC realizado durante el año 2013. En el control del VIH-1 se remitieron 5 estándares, de los que 1 (plasma humano seronegativo) no contenía el virus, y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 2-5 log10 copias/ml; 2 de ellos eran idénticos, con el fin de analizar la repetibilidad. Una parte significativa de los laboratorios obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml) dependiendo del estándar y del método empleado, en promedio el 25% de los centros. La repetibilidad fue excelente y más del 98,9% de los laboratorios obtuvo resultados aceptables (D < 0,5 log10 copias/ml). En los controles de VHC y VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes, alrededor del 82% en el caso del VHC y del 78% en el del VHB, obtuvo ambos resultados dentro de los límites de la media ± 1,96 DE log10 UI/ml. Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos, incluyendo la fase postanalítica. Debido a la variabilidad interlaboratorio es aconsejable utilizar un mismo método y el mismo laboratorio en el seguimiento de los pacientes


Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load HCV determinations are among the most relevant markers for the follow up of patients infected with these HIV-1 viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2013 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (25% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 78% in the HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up


Assuntos
Feminino , Humanos , Masculino , Carga Viral/métodos , Carga Viral , HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Vírus da Hepatite B/patogenicidade , Controle de Qualidade , Reprodutibilidade dos Testes , Carga Viral/tendências , Anticorpos Anti-Hepatite C , Resultado do Tratamento
17.
Enferm Infecc Microbiol Clin ; 32 Suppl 1: 1-8, 2014 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-24630577

RESUMO

The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2012 controls. As a whole, the results obtained in 2012 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests.


Assuntos
Técnicas Microbiológicas/normas , Controle de Qualidade , Humanos
18.
Enferm Infecc Microbiol Clin ; 32 Suppl 1: 9-14, 2014 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-24630578

RESUMO

Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2012 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (22.3% on average) obtained values out of the accepted range (mean±0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (Δ < 0.5 log10 copias/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 84% in the case of HCV and 88% in the HBV, obtained all the results within the accepted range (mean±1.96 SD log10 UI/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up.


Assuntos
HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Controle de Qualidade , Carga Viral/normas , Humanos
19.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 32(supl.1): 1-8, feb. 2014. tab
Artigo em Espanhol | IBECS | ID: ibc-134453

RESUMO

Se presenta el análisis anual de los resultados remitidos durante el año 2012 por los participantes inscritos en el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC), que incluye las áreas de bacteriología, serología, micología, parasitología, micobacterias, virología y microbiología molecular. Los resultados obtenidos por los centros participantes resaltan, de nuevo, la adecuada capacitación de la inmensa mayoría de los laboratorios españoles de microbiología clínica, como ya venía sucediendo en los últimos años. A pesar de ello, el programa muestra que es posible obtener un resultado erróneo, incluso en determinaciones de la mayor trascendencia y en cualquier laboratorio. Una vez más se destaca la importancia de complementar el control interno que cada laboratorio lleve a cabo con estudios de intercomparación externos, como los que ofrece el Programa SEIMC (AU)


The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2012 controls. As a whole, the results obtained in 2012 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests (AU)


Assuntos
Técnicas Microbiológicas/normas , Técnicas Bacteriológicas/normas , Técnicas de Tipagem Micológica/normas , Testes Sorológicos/normas , Virologia/normas , Parasitologia/normas , Controle de Qualidade , Padrões de Referência , Ensaio de Proficiência Laboratorial/métodos
20.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 32(supl.1): 9-14, feb. 2014. tab
Artigo em Espanhol | IBECS | ID: ibc-134454

RESUMO

Las determinaciones de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1), de la hepatitis C (VHC) y de la hepatitis B (VHB) son marcadores microbiológicos fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología disponen de herramientas que garantizan la fiabilidad de sus resultados; entre ellas se encuentran los programas de intercomparación externos, como el Programa de Control de Calidad de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC). En el presente número se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de carga viral de estos virus, incluyendo el genotipado del VHC, realizado durante el año 2012.En el control de VIH-1 se remitieron 5 estándares, de los que 1 (plasma humano seronegativo) no contenía el virus y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones de entre 2-5 log10 copias/ml; 2 de ellos eran idénticos, con el fin de analizar la repetibilidad. Una parte significativa de los laboratorios obtuvo de uno a varios resultados fuera de los límites aceptables (media ± 0,25 log10 copias/ml), dependiendo del estándar y del método empleado, en promedio el 22,3% de los centros. La repetibilidad fue excelente y más del 98,9% de los laboratorios obtuvo resultados aceptables (Δ < 0,5 log10 copias/ml). En los controles de VHC y VHB se remitieron 2 estándares con diferente contenido del virus. La mayor parte de los participantes, alrededor del 84% en el caso del VHC y del 88% en el del VHB, obtuvo ambos resultados dentro de los límites de la media ± 1,96 DE log10 UI/ml. Los resultados obtenidos ponen de manifiesto la utilidad de los controles externos para asegurar la calidad de los resultados analíticos, incluyendo la fase postanalítica. Debido a la variabilidad interlaboratorio es aconsejable utilizar un mismo método y el mismo laboratorio en el seguimiento de los pacientes


Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2012 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (22.3% on average) obtained values out of the accepted range (mean±0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (Δ < 0.5 log10 copias/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 84% in the case of HCV and 88% in the HBV, obtained all the results within the accepted range (mean±1.96 SD log10 UI/mL).Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up (AU)


Assuntos
Humanos , Carga Viral/instrumentação , Virologia/normas , Infecções por HIV/microbiologia , Hepatite B Crônica/microbiologia , Hepatite C Crônica/microbiologia , Vírus da Hepatite B/isolamento & purificação , Hepacivirus/isolamento & purificação , Controle de Qualidade , Ensaio de Proficiência Laboratorial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...